Eurovent Certification for Air-to-Air Heat Recovery Units

Eurovent is the European certification body for HVACR products. Its certification program for air handling units and heat-recovery sections gives buyers independent verification of performance.

What it is

Manufacturers submit units for independent laboratory testing; certified performance is published in the Eurovent Certified Performance (ECP) database.

Why trust it

It closes the gap between a brochure number and a measured number. Certified units are re-tested periodically to keep the listing honest.

What is verified

Element Certified?
Sensible effectiveness Yes
Latent effectiveness (ERV) Yes
Air leakage Yes
Pressure drop Yes

How to verify

Search the Eurovent ECP database by model and compare the certified sensible/latent effectiveness and pressure drop against your specification before purchase.

Common pitfall

Accepting a non-certified figure for a large AHU. Above a certain size the energy and compliance risk justifies a certified unit.

AHRI 1060 - Performance Rating of Energy Recovery Ventilators

AHRI Standard 1060 covers the performance rating of air-to-air energy recovery ventilators, both ERV and HRV, in North America.

Scope

It sets rating conditions - inlet temperatures, humidities, and airflows - and the metrics used to publish certified performance.

Key metrics

Metric Condition
Sensible effectiveness Defined winter/summer points
Latent effectiveness For ERV, defined points
Apparatus dew point Frost / condensation limit

Rating vs testing

AHRI 1060 defines what to rate; ASHRAE 84 defines how to test. Together they give a certified, comparable number.

How to apply

Use AHRI 1060 ratings to compare North American units on equal footing, and confirm the rating point is close to your design condition.

EN 16798 - Building Energy Performance

Scope

EN 16798 is the European standard family for the energy performance of buildings, covering ventilation, indoor environmental quality, and the role of heat recovery in cutting heating and cooling demand.

Where Recovery Fits

The standard recognises that ventilation is a major energy load because it brings in untreated outside air. Recovering energy from the exhaust stream is one of the most cost-effective ways to meet its targets.

Practical Impact

  • Sets acceptable indoor air quality thresholds
  • Encourages high-efficiency recovery in new and renovated buildings
  • Feeds national building codes and incentive schemes

For Specifiers

When a project must demonstrate compliance with EN 16798, the recovery effectiveness you choose directly affects the calculated energy use. Document the EN 308 rating you relied on so the calculation can be audited.

EN 308 - Heat Exchanger Test Methods

What EN 308 Covers

EN 308 sets the test method for air-to-air heat recovery components such as plate exchangers, rotary wheels, and heat pipes. It defines how to measure temperatures and flow rates and how to calculate sensible and latent effectiveness.

Why It Matters

Without a fixed method, every manufacturer could test under conditions that flatter their product. EN 308 gives a common basis so that two datasheets can be compared like for like.

Key Measurements

  • Supply and exhaust airflow rates
  • Inlet and outlet dry-bulb and wet-bulb temperatures
  • Effectiveness at several operating points, not just one

Reading a Datasheet

A credible EN 308 rating states the test airflow, the temperature difference, and the face velocity. If those are missing, the percentage is hard to trust. Look for the performance curve, which shows behaviour at part load where most equipment actually runs.

Heat Pipe vs Plate Heat Exchanger

What a Heat Pipe Does

A heat pipe is a sealed tube with a small amount of working fluid. Heat at one end evaporates the fluid; the vapour travels to the cold end, condenses, and releases the energy. A bundle of these tubes forms a passive exchanger with no motor and no mixing of airstreams.

Strengths

  • No moving parts - essentially maintenance free
  • Air streams never mix, so contamination risk is zero
  • Works well in harsh or dirty environments

Weaknesses

  • Lower effectiveness (typically 50 to 65 percent)
  • Does not transfer moisture (sensible only)
  • Less compact than a modern plate core at equal duty

Best Fit

Heat pipes suit locations where reliability matters more than peak efficiency: remote sites, industrial extracts, and systems where a failed motor would be expensive. For maximum energy savings in a normal building, a plate or rotary unit usually wins.

Counterflow vs Crossflow Plate Exchangers

How the Air Moves

In a counterflow core the two airstreams run in opposite directions; in a crossflow core they cross at right angles. Counterflow lets the cold outgoing air meet the coldest part of the incoming stream, squeezing out more energy.

Effectiveness Difference

  • Crossflow plate: typically 60 to 65 percent sensible
  • Counterflow plate: typically 70 to 75 percent sensible

Trade-offs

Crossflow Counterflow
Effectiveness Good Better
Manufacturing Simpler, cheaper More complex
Pressure drop Lower at equal size Slightly higher

Which to Specify

Crossflow fits most commercial ventilation where space and cost matter. Counterflow is the choice when every point of effectiveness counts, such as in passive-house or low-temperature heating systems.

Sensible vs Enthalpy (Total) Heat Recovery

Two Forms of Energy

Air carries energy as dry-bulb heat (sensible) and as water vapour (latent). Sensible recovery moves only the first; enthalpy recovery moves both.

Why It Matters

In a humid climate, a large part of the cooling load is the energy needed to remove moisture. A sensible-only exchanger leaves that moisture in the incoming air, so the cooling coil still works hard. An enthalpy exchanger pre-conditions both temperature and humidity.

Typical Results

  • Sensible plate: ~70 percent temperature recovery, 0 percent moisture
  • Enthalpy wheel: ~80 percent temperature, ~70 percent moisture
  • Membrane plate: ~70 percent temperature, ~60 percent moisture

When Sensible Is Enough

In dry or cold climates, humidity control is not the bottleneck, so a simpler sensible plate core is the cost-effective choice.

When Enthalpy Pays Off

In tropical or subtropical buildings, enthalpy recovery often halves the dehumidification load and shortens the payback of the whole system.

Plate vs Rotary Heat Exchanger: Which to Specify

When you specify an air-to-air heat recovery unit, the first fork in the road is fixed plate versus rotary (enthalpy) wheel. Both recover energy between supply and exhaust airstreams, but they behave very differently under real duty.

Side-by-side

Feature Plate (fixed) Rotary (wheel)
Recovery type Sensible only Sensible + latent (enthalpy)
Peak sensible effectiveness Up to ~90% Up to ~85%
Latent recovery None Yes (with desiccant wheel)
Frost risk Low in moderate climate Higher; needs purge sector
Airstream crossover None (separate plates) Small carryover (~1-3%)
Footprint Compact, shallow Needs axial depth for wheel
Maintenance Very low Periodic wheel cleaning
First cost Lower Higher

When to choose a plate exchanger

Choose a plate core when airstreams are adjacent, you only need sensible recovery, contamination between streams must be zero, and budget is tight. Cold, dry climates are ideal because there is no moving part to freeze.

When to choose a rotary wheel

Choose a rotary wheel when you must control humidity (humid summers, museums, pools) or when the two airstreams are far apart and a plate will not fit. Accept the small purge-sector leakage as the price of latent recovery.

Decision summary

Pick plate for clean, sensible-only, contamination-free duties; pick rotary when latent recovery or distant airstreams dominate. See our plate and rotary selection guides for sizing.

Heat Exchanger Sizing Checklist

Step 1 - Define the Duty

  • Supply and exhaust airflow (they should be close to balanced for recovery to work)
  • Outdoor winter and summer design temperatures
  • Indoor setpoint and allowable supply-air temperature

Step 2 - Pick the Technology

  • Dry climate, no humidity need - sensible plate core
  • Humid climate, moisture control - enthalpy wheel or membrane plate
  • Long life, no moving parts - heat pipe
  • Very high effectiveness needed - rotary wheel

Step 3 - Check the Limits

  • Pressure drop versus fan power budget
  • Frost risk below about -2 C exhaust dewpoint
  • Space available for the core or wheel

Step 4 - Verify

Confirm the selection against an EN 308 or AHRI 1060 rating at your actual operating point, not the headline number. A sizing tool that shows the curve is worth more than a single percentage.

Air-to-Air Heat Exchanger Standards Index

Testing Standards

  • EN 308 - test methods for air-to-air heat recovery components; the basis for published effectiveness.
  • EN 16798 - energy performance of buildings, including ventilation and recovery requirements.
  • AHRI 1060 - rating of air-to-air energy recovery ventilation equipment (North America).

Certification

  • Eurovent - independent certification that the claimed performance is real.
  • CE marking - conformity with applicable EU directives.

Efficiency Regulation

  • ErP / Ecodesign Lot 6 - minimum efficiency requirements for ventilation units with heat recovery in the EU.
  • ASHRAE 90.1 - energy standard that sets recovery thresholds by climate zone.

How to Read a Citation

When a datasheet cites EN 308, it should state the test conditions (airflow, temperature difference, face velocity). A bare standard number without conditions tells you little. Our Standards section explains each document in plain language.